Read LG 32CS460C Service Manual online
- 15 -
4.7. LAN PORT INSPECTION(PING TEST)
4.7.1. Equipment setting
1) Play the LAN Port Test PROGRAM.
2) Input IP set up for an inspection to Test
Program.
*IP Number : 12.12.2.2
4.7.2. LAN PORT inspection (PING TEST)
1) Play the LAN Port Test Program.
2) connect each other LAN Port Jack.
3) Play Test (F9) button and confirm OK Message.
4) Remove LAN CABLE
4.8. Outgoing condition Configuration
■ When pressing IN-STOP key by SVC remocon, Red LED
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
4.9 GND & Hi-pot test
Confirm whether is normal or not when between power
board's ac block and GND is impacted on 1.5kV(dc) or
2.2kV(dc) for one second.
■ GND TEST = POWER CORD GND and SIGNAL CABLE
GND
■ Hi-pot TEST = POWER CORD GND and LIVE&NUETRAL
■ Test Process
(1) Check the POWER CABLE and SIGNAL CABLE insertion
condition.
(2) Connect the AV JACK Tester
(3) Controller(GWS103-4) on
(4) GND TEST(Auto)
- If Test is failed, Buzzer operate
- If Test is passed, execute next process(HI-pot test)
- Remove A/V CORD from A/V JACK BOX
(5) HI-POT test(Auto)
- If Test is failed, Buzzer operate
- If Test is passed, GOOD Lamp on and move to next
process automatically.
5. EYE-Q function check
Step1) Turn on TV.
Step2) Press “P-only” key, enter to power only mode and
escape the “P-only” Mode by pressing “Exit” key
Step3) Press “Tilt” key, entrance to Local Dimming mode.
Step4) At the Local Dimming mode, module Edge Backlight
moving Top to bottom Back light of module moving
Step5) confirm the Local Dimming mode
Step6) Press “Exit” key
6. 3D Function Test
(Pattern Generator MSHG-600, MSPG-6100 [SUPPORT
HDMI1.4])
* HDMI mode NO. 872 , pattern No.83
1) Please input 3D test pattern like below (HDMI mode NO.
872 , pattern No.83)
2) When 3D OSD appear automatically , then select OK
button.
3) Don’t wear a 3D Glasses, Check the picture like below
Click on the first or last page to see other 32CS460C service manuals if exist.