Read LG 26LU50FR-LA / 26LU50FR-TA (CHASSIS:LP91A) Service Manual online
5.3. Adjustment of White Balance
(For Manual adjustment)
(1) Color analyzer(CA100+, CA210) should be used in the
calibrated ch by CS-1000.
(2) Operate the zero-calibration of the CA100+ or CA-210,
then stick sensor to the module when adjusting.
(3) For manual adjustment, it is also possible by the following
sequence.
1) Select white pattern of heat-run by pressing “POWER
ON” key on remote control for adjustment then operate
heat run longer than 15 minutes. (If not executed this
step, the condition for W/B may be different.)
heat run longer than 15 minutes. (If not executed this
step, the condition for W/B may be different.)
2) Push “Exit” key.
3) Change to the AV mode by remote control.
4) Input external pattern (85% white pattern)
5) Push the ADJ key -> Enter “0000” (Password)
6) Select “3. W/B ADJUST”
7) Enter the W/B ADJUST Mode
8) Stick the sensor to the center of the screen and select
3) Change to the AV mode by remote control.
4) Input external pattern (85% white pattern)
5) Push the ADJ key -> Enter “0000” (Password)
6) Select “3. W/B ADJUST”
7) Enter the W/B ADJUST Mode
8) Stick the sensor to the center of the screen and select
each items (Red/Green/Blue Gain and Offset) using
D
/
E
(CH +/-) key on R/C..
9) Adjust R/ G/ B Gain using
F
/
G
(VOL +/-) key on R/C.
10) Adjust three modes all (Cool / Medium / Warm) : Fix
the one of R/G/B gain and change the others
11) When adjustment is completed, Enter “COPY ALL”.
12) Exit adjustment mode using EXIT key on R/C.
12) Exit adjustment mode using EXIT key on R/C.
* CASE
First adjust the coordinate far away from the target value(x, y).
1) x, y > target
1) x, y > target
i) Decrease the R, G.
2) x, y < target
i) First decrease the B gain,
ii) Decrease the one of the others.
ii) Decrease the one of the others.
3) x > target, y < target
i) First decrease B, so make y a little more than the target.
ii) Adjust x value by decreasing the R
ii) Adjust x value by decreasing the R
4) x < target, y > target
i) First decrease B, so make x a little more than the target.
ii) Adjust x value by decreasing the G
ii) Adjust x value by decreasing the G
(4) Standard color coordinate and temperature when using the
CA100+ or CA210 equipment
To check the Coordinates of White Balance, you have to
measure at the below conditions.
Picture Mode : select Vivid and change
Dynamic Contrast : Off
Dynamic Colour : Off
-> Picture Mode : changee : Vivid
-> Vivid (User)
(If you miss the upper condition, the coordinates of W/B
can be lower than the spec.)
measure at the below conditions.
Picture Mode : select Vivid and change
Dynamic Contrast : Off
Dynamic Colour : Off
-> Picture Mode : changee : Vivid
-> Vivid (User)
(If you miss the upper condition, the coordinates of W/B
can be lower than the spec.)
- 13 -
Coordinate
Mode
x y
Temp uv∆
Cool 0.276±0.002
0.283±0.002
11,000K 0.000
Medium 0.285±0.002 0.293±0.002
9,300K
0.000
Warm 0.313±0.002 0.329±0.002
6,500K 0.003