4.2. EYE-Q function check
(1) Turn on TV.
(2) Press “EYE” key on Adjustment remote control.
(3)  Cover the Eye Q sensor at the front of set for 6 seconds.
(4)  Check  the  value  of  Sensor  Data.  It  must  be  below  10.  If 
not so, the Eye Q sensor may have some defect. Change 
the Eye Q sensor.
(5)  Wait  for  6  seconds  after  withdrawing  form  the  Eye  Q 
sensor.
(6)  Check  the  value  of  Backlight.  It  must  rise.  If  not  so,  the 
Eye Q sensor may have some defect. Change the Eye Q 
sensor.
4.3. Outgoing condition Configuration
■  When  pressing  IN-STOP  key  by  SVC  remocon,  Red  LED 
are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
5. GND and HI-POT Test
5.1. GND & HI-POT auto-check preparation
-  Check the POWER cable and SIGNAL cable insertion condition
5.2. GND & HI-POT auto-check
(1)  Pallet moves in the station. (POWER CORD / AV CORD is 
tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto) 
- If Test is failed, Buzzer operates.
-  If Test is passed, execute next process (Hi-pot test). (Re-
move A/V CORD from A/V JACK BOX) 
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next proc-
ess automatically.
5.3. Checkpoint
(1) Test voltage
- GND: 1.5 KV / min at 100 mA
- SIGNAL: 3 KV / min at 100 mA
(2) TEST time: 1 second
(3) TEST POINT
- GND Test = POWER CORD GND and SIGNAL CABLE GND
- Hi-pot Test = POWER CORD GND and LIVE & NEUTRAL.
(4) LEAKAGE CURRENT: At 0.5 mArms
6. Model name & Serial number D/L
▪ Press "Power on" key of service remote control.
(Baud rate : 115200 bps)
▪ Connect RS232 Signal Cable to RS-232 Jack.
▪ Write Serial number by use RS-232.
▪  Must  check  the  serial  number  at  the  Diagnostics  of  SET  UP 
menu. (Refer to below).
6.1. Signal Table
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +...+ Data_n
Delay : 20ms
6.2. Comand Set
* Description
FOS Default write : <7mode data> write
Vtotal,  V_Frequency,  Sync_Polarity,  Htotal,  Hstart,  Vstart,  0, 
Phase
Data write :  Model Name and Serial Number write in EEPROM,.
6.3. Method & notice
(1) Serial number D/L is using of scan equipment.
(2)  Setting  of  scan  equipment  operated  by  Manufacturing 
Technology Group.
(3)  Serial number D/L must be conformed when it is produced in 
production  line,  because  serial  number  D/L  is  mandatory  by 
D-book 4.0.
 
 
 
 
CMD
LENGTH
ADH
ADL
DATA_1
. . .
Data_n
CS
DELAY
Adjust mode
CMD(hex)
LENGTH(hex)
Description
EEPROM WRITE
A0h
84h+n
n-bytes Write (n = 1~16)