(2) DIGITAL DATA(HDMI-1) 256Byte
(3) DIGITAL DATA(HDMI-2) 256Byte
(4) DIGITAL DATA(HDMI-3) 256Byte
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01
**: Month : Controlled / Data:00
***:Year : Controlled
****:Check sum
4.7. Outgoing condition Configuration
When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off. (Must
not AC power OFF during blinking)
Confirm whether is normal or not when between power
board's ac block and GND is impacked on 1.5kV(dc) or
2.2kV(dc) for one second
5. Adjustment Command
5.1. I2C(100K BPS)
5.2. COMMUNICATION START
# Until ACK BIT goes LOW, Repeat it.
5.3. Command form
Command form use DDC2AB standard communication
protocol.
a. LEN : DATA BYTE number to send
b. CMD : Command language theat monitor executes.
c. VAL : FOS DATA
d. CS : Dada’s CHECKSUM that transmit
e. DELAY : 50Ms
f. A : Acknowledge
5.5. EEPROM DATA READ
(1) Signal TABLE
(2) Command Set
* Purpose : To  read(84h) the appointment Address of
E2PROM by 128(80h)-byte
- 13 -
START
6E
A
STOP
50Ms
START
6E A 50
A
A
A
A
A
A
A
30
00
CS
STOP
LEN
CMD
VAL
128 Bytes
Delay 100ms
EEPROM READ
E7
A0
0
0-Page   0~7F  Read
80
0-Page  80~FF  Read
A2
0
1-Page   0~7F  Read
80
1-Page  80~FF  Read
A4
0
2-Page   0~7F  Read
80
2-Page  80~FF  Read
A6
0
3-Page   0~7F  Read
80
3-Page  80~FF  Read
Adjustment item
CMD(hex) ADH(hex) ADL(hex)
Details
Page of 28
Display