19LU5000, 19LU5010, 19LU5020 (CHASSIS:LD91A) - LG TV Service Manual (repair manual). Page 13

Read LG 19LU5000 / 19LU5010 / 19LU5020 (CHASSIS:LD91A) Service Manual online

- 13 -
4.5. V-COM Adjust(Only 37/42/47LH4000-ZA)
- Why need Vcom adjustment?
A
The Vcom (Common Voltage) is a Reference Voltage of
Liquid Crystal Driving.
-> Liquid Crystal need for Polarity Change with every frame.
- Adjust sequence
· After enter Service Mode by pushing “ADJ” key.
· Enter V-Com Adjust mode by pushing “
G
” key at “10. V-
Com”
· As pushing the right or the left button on the remote
controller, Find the V-COM value that is stopped the Flicker.
· If there is no flicker at default value, turn down or turn up at
least 20 step and check the flicker. Then go to the default
value.
· Push the store button by “OK” key in the ADJ remocon.
4.6. Outgoing condition Configuration
- When pressing IN-STOP key by SVC remocon, Red LED are
blinked alternatively. And then Automatically turn off.
(Must not AC power OFF during blinking)
Confirm whether is normal or not when between power
board's ac block and GND is impacted on 1.5kV(dc) or
2.2kV(dc) for one second
5. Serial number D/L
• press “Power on” key of service remocon.
(Baud rate : 115200 bps)
• Connect RS232 Signal Cable to RS-232 Jack.
• Write Serial number by use RS-232.
• Must check the serial number at the Diagnostics of SET UP
menu. (Refer to below).
5.1. Signal TABLE
CMD : A0h
LENGTH : 85~94h (1~16 bytes)
ADH : EEPROM Sub Address high (00~1F)
ADL : EEPROM Sub Address low (00~FF)
Data : Write data
CS : CMD + LENGTH + ADH + ADL + Data_1 +…+ Data_n
Delay : 20ms
5.2. Command Set
* Description
FOS Default write : <7mode data> write
Vtotal, V_Frequency, Sync_Polarity, Htotal, Hstart, Vstart, 0,
Phase
Data write : Model Name and Serial Number write in
EEPROM,.
5.3. Method & notice
1) Serial number D/L is using of scan equipment.
2) Setting of scan equipment operated by Manufacturing
Technology Group.
3) Serial number D/L must be conformed when it is produced
in production line, because serial number D/L is mandatory
by D-book 4.0.
CMD 
LENGTH
ADH 
ADL 
DATA_1
. . . 
Data_n 
CS 
DELAY 
No. Adjust 
mode 
CMD(hex)
LENGTH(hex) 
Description 
EEPROM WRITE 
A0h 
84h+n 
n-bytes Write (n = 1~16) 
Row  Li ne
Column  Line
C
LC
C
ST
Pane l
S
Y
S
T
E
M
Gat
e
 Driv
e
 IC
So urce D r i v e  I C
Circuit Block
Ti m i n g  
Co nt r o ll e r
Po w e r  
Blo ck
V
COM
Ga mma
Re f e r e nce V o ltage
Gamm a R eference
Volta ge
Da ta (R ,G,B ) & C ont ro l s ignal
Con t rol si gnal
Data (R ,G,B ) &
Con t rol si gnal
In
te
r
fa
c
e
TFT
Po w e r  I n p u t
Power Input
Da t a  I n p u t
Da t a  I n p u t
V
COM
Liquid 
Crys tal
V
COM
(Visual Adjust and control the Voltage level)