- 9 -
8. USB S/W Download
* optional, Service only
(1) Put the USB Stick to the USB socket.
(2) Automatically detecting update file in USB Stick.
-  If your downloaded program version in USB Stick is lower 
than that of TV set, it didn’t work. 
       Otherwise USB data is automatically detected.
(3) Show the message “Copying files from memory”.
(4) Updating is starting.
(5) Updating Completed, the TV will restart automatically.
(6)  If  your TV  is  turned  on,  check  your  updated  version  and 
Tool option. (explain the Tool option, next stage)
*  If  downloading  version  is  more  high  than  your TV  have, 
TV  can  lost  all  channel  data.  In  this  case,  you  have  to 
channel recover. if all channel data is cleared, you didn't 
have a DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
1) Push "IN-START" key in service remote control.
2) Select "Tool Option 1" and push "OK" key.
3) Punch in the number. (Each model has their number.)
9. Optional adjustments
9.1. Manual White balance Adjustment
9.1.1. Adjustment condition and cautionary items
(1)  Lighting condition in surrounding area surrounding lighting 
should  be  lower  10  lux. Try  to  isolate  adj.  area  into  dark 
surrounding.
(2)  Probe location: Color Analyzer (CA-210) probe should be 
within 10cm and perpendicular of the module surface.
     (80°~ 100°)
(3) Aging time
1)  After Aging  Start,  Keep  the  Power  ON  status  during  5 
Minutes.
2)  In case of LCD, Back-light on should be checked using 
no signal or Full-white pattern.
9.1.2. Equipment
(1)  Color Analyzer: CA-210 (NCG: CH 9 / WCG: CH12 / LED: 
CH14)
(2) Adj. Computer(During auto adj., RS-232C protocol is needed)
(3) Adjust Remot control
(4) Video Signal Generator MSPG-925F 720p/216-Gray 
     (Model: 217, Pattern: 78) 
9.1.3. Adjustment
(1) Set TV in Adj. mode using POWER ON.
(2)  Zero Calibrate the probe of Color Analyzer, then place it on 
the center of LCD module within 10cm of the surface.
(3)  Press ADJ  key  →  EZ  adjust  using  adj.  R/C  →  6.  White-
Balance then press the cursor to the right (Key►). When 
Key(►)  is  pressed  216  Gray  internal  pattern  will  be 
displayed.
(4)  One of R Gain / G Gain / B Gain should be fixed at 192, 
and the rest will be lowered to meet the desired value.
(5)  Adj. is performed in COOL, MEDIUM, WARM 3 modes of 
color temperature.
■  If internal pattern is not available, use RF input. In EZ Adj. 
menu 6.White Balance, you can select one of 2 Test-pattern: 
 ON,  OFF.  Default  is  inner(ON).  By  selecting  OFF,  you  can 
adjust using RF signal in 216 Gray pattern.
Page of 28