Read JBL MA6002 EMC - CB Certificate online
File
No.
F30132-00-00HM
, page 14 of 20
mikes-testingpartners gmbh
x Tel.:09424-94810 x Fax:09424-9481240
Rev. Nr. 1.0
Test specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- all external locations accessible by hand
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- see photo documentation of the test set-up
- horizontal plate (HCP)
- vertical coupling plate (VCP)
5.4.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave was disturbed.
Operation mode: 1 kHz 1/8 power.