5. ELECTROSTATIC DISCHARGE IMMUNITY TEST 
The measurement of the Immunity Against Electrostatic Discharge was performed in a shield room. 
Test Location: Shielded Room (S-01). 
Date: January 20, 2004 
5.1 Operating environment 
Ambient temperature 
19 [°C] 
(15 – 35 °C) 
Relative humidity 
40 [%] 
(30 – 60 %) 
Atmospheric pressure 
1005 [mbar] 
(860 – 1060 mbar) 
5.2 Test set-up 
The EUT and all local support equipment were placed on non-metallic support 0.8m above a reference ground plane (RGP) 
and were put into operation according to the specified operating mode. 
A photo of the test set-up is included in appendix II. 
5.3 Measurement uncertainty 
The uncertainty of the applied electrostatic discharges is within the tolerance specified by the standard. 
5.4 Test equipment used 
 
Model Number 
Manufacturer 
Description 
Serial Number 
„ -  ESS-630A 
NOISE LABORATORY 
ESD Simulator 
A863019 
„ -  TC-815D(F) 
NOISE LABORATORY 
ESD Gun 
H567773 
All test equipment used is calibrated on a regular basis. 