Read JBL GTO 75.2 (serv.man4) EMC - CB Certificate online
Page 8 of 9
File No.: E042R-012
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: AUX Output R-CH
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.80
26.40
-
1.35
0.98
28.73
-
45.03
35.03
53.00
25.50
-
0.29
1.12
26.91
-
45.85
35.85
- Coupling Location
: Plus(+) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.90
38.50
27.50
1.42
0.96
40.88
29.88
45.07
35.07
35.40
36.10
25.40
3.68
0.92
40.70
30.00
45.20
35.20
46.70
26.90
-
0.59
1.13
28.62
-
45.62
35.62
- Coupling Location
: Minus(-) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.90
36.10
27.00
1.42
0.96
38.48
29.38
45.07
35.07
33.00
37.80
30.00
1.49
0.94
40.23
32.43
45.11
35.11
36.80
28.50
-
3.60
1.01
33.11
-
45.25
35.25
- Coupling Location
: Remote Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.10
31.60
24.10
1.37
0.98
33.95
26.45
45.04
35.04
44.00
25.70
-
1.24
1.20
28.14
-
45.52
35.52
Note: Q.P : Quasi-peak, AVE : Average
Q.P Limit [dB(pW)]: Freq.(MHz) / 27 + 43.89
A.V Limit [dB(pw)]: Freq.(MHz) / 27 + 33.89
In case that Quasi-Peak values are under the Average limit, Average data are not recorded.
Tested by: Eung-Chan, Kim / Test Engineer