GTO 2000 (serv.man2) - JBL Car Audio Service Manual (repair manual). Page 3

Read JBL GTO 2000 (serv.man2) Service Manual online

Test Conditions and Notes
All tests to be done, unless otherwise specified, from 30Hz to 320Hz at 14.4V DC into 2 ohm loads and adjust 
the units gain so that with a .100 volt input signal the unit is at its maximum rated output. All measurements 
will be done using an Audio precision system one and the supply voltage.
An A+ line voltage of 14.4V DC shall be applied to the unit under test for all measurements unless otherwise 
specified. The voltage applied to the unit shall be measured at the power connection on the Amplifier.
Signal  Source
Unless otherwise specified, all tests shall be conducted with the Audio Signal Generator output configured to 
be balanced, less than or equal to 50 ohm source impedance, and floating. The signal source "GND" shall be  
connected to the Amplifier PWR GND at the Amplifier.
Output Load
Unless otherwise specified, all tests shall be conducted with 2 ohm resistive loads having less than 0.1% 
reactive components at any frequency below 1Kz. Each resistor shall have a value that remains within 0.1% 
while dissipating the rated output of the unit under test.
Power Indicator LED steadily illuminates for normal operation.
RCA-jacks, Speaker-and power terminals gold-plated
2 ohm stability(stereo mode)
Bridging capability(min.4 ohm)
Tri-mode operation(min.4 ohm)
Protection circuitry thermal-and electrical overload.short-circuit.DC-offset
HPF variable high pass filter(HPF)30-320Hz.12dB/oct.
LPF variable low pass filter(LPF)30-320Hz.12dB/oct.
+6dB(at 45Hz)Bass boost