Read JBL GTO 14001 (serv.man2) EMC - CB Certificate online
Report #HL-E07062714 Page 8 of 28 Model:
GTO14001
Harman Consumer Group
Holytech (HK) Certification Co., Limited
Flat/Rm 1001 ,10/F., Taiyau building 181 Johnston Road, Wanchai, HK
TEL:00852-36458129 FAX:00852-36458092
TEL:00852-36458129 FAX:00852-36458092
3 - Standards Applicable for Testing
The standards used were EN 55013 Class B, for emissions & EN 55020 for immunity.
3.1 EMI
Table 1 : Tests Carried Out Under EN 55013: 2001+A2:2006
Standard Status
EN 55013: 2001+A2:2006
Mains Terminal Disturbance Voltage
×
EN 55013: 2001+A2:2006
Antenna Terminal Disturbance Voltage
×
EN 55013: 2001+A2:2006
Disturbance Power
√
√
Indicates that the test is applicable
×
Indicates that the test is not applicable
3.2 EMS
Test Project
S1 S2V S2I S3 S4
Result of Test
×
√
×
√
×
√
Indicates that the test is applicable
×
Indicates that the test is not applicable
Table 3 : Tests Carried Out Under EN 55020:2000/A2:2005
Standard Status
EN 61000-4-2:1995/A2:2001
Electro-static discharge
√
EN 61000-4-3:2006
Radio frequency EM fields (80MHz to 1GHz)
√
EN 61000-4-4:2004
Fast transients
×
Click on the first or last page to see other GTO 14001 (serv.man2) service manuals if exist.