DA 4002 (serv.man2) - JBL Car Audio Service Manual (repair manual). Page 3

Read JBL DA 4002 (serv.man2) Service Manual online

Test Conditions and Notes
2-Channel Operation
Simultaneous Stereo +Mono Operation
Advanced MOSFET Oversized Floating Rail Power Supply 
Floating Ground Factory - Head - Unit Speaker - Level input
Variable Input Sensitivity (250mV - 4V)
Fully Complementary Output Stage with Class-A Voltage Amplification
Gold-plated Power, Input and Output Connectors
2-Ohm Stable (Stereo)
Power-on Indicator Badge
Fill Programmable 12dB per Octave Crossover (Low-pass,High-pass,Thru pass)
All tests to be done, unless otherwise specified, from 20KHz to 20KHz at 14.4V DC into 4 ohm loads and adjust 
the units gain so that with a .775 volt input signal the unit is at its maximum rated output. All measurements 
will be done using an Audio precision system one and the supply voltage.
An A+ line voltage of 14.4V DC shall be applied to the unit under test for all measurements unless otherwise 
specified. The voltage applied to the unit shall be measured at the power connection on the Amplifier.
Signal  Source
Unless otherwise specified, all tests shall be conducted with the Audio Signal Generator output configured to 
be balanced, less than or equal to 50 ohm source impedance, and floating. The signal source "GND" shall be  
connected to the Amplifier PWR GND at the Amplifier.
Output Load
Unless otherwise specified, all tests shall be conducted with 4 ohm resistive loads having less than 10% 
reactive components at any frequency below 75KHz. Each resistor shall have a value that remains within 1% 
while dissipating the rated output of the unit under test.
Power Indicator LED(on amp chassis top)-LED steadily illuminates for normal operation. LED blinks when
protection circuitry is engaged, and during power up.
2
Features
Multichannel Automotive Amplifier
DA 4002
Page of 15
Display