Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  .............:  220-230 
— 
 
Frequency (Hz) ........................................................:  50 – 60 
— 
 
Ambient temperature (
o
C) .......................................:  23 
— 
 
No. 
component 
No. 
fault 
dT (K) / Component 
Other results 
(include description and test duration) 
Power output 
Max 
amp. 
Un = 253 V, Pn= 222 W, In= 1.3 A Max. 
U
out= 
37 V 
After 1h 46min the apparatus began to 
switch between ON and stand-by mode 
periodically. 
The test was interrupted after 4h. 
 
No hazard. 
C19 
sc 
N/A 
Un = 198 V 
F501 opened immediately. Q11 damaged. 
No hazard. 
Q11 (d-g) 
sc 
N/A 
Un = 198 V 
F501 opened immediately. Q10, Q10B, 
Q11 damaged. 
No hazard. 
R6 
N/A 
Un = 253 V, Pn = 111-172 W, I
F1 
=0.6-
0.9A within 2min the apparatus switched 
to standby mode. Test time 2min.  
No hazard. 
Q5B (c-b) 
sc 
N/A 
Un = 253 V, Pn = 60 W 
Uout decreased to 6.5 V. The negative 
part of the output signal disappeared. Test 
time 5min. No hazard. 
6a 
C134 
sc 
N/A 
Un = 253 V 
R241 opened after 2s. No hazard. 
6b 
C134 
sc 
N/A 
Un = 198 V, Pn = 9 W 
R241 opened after 16 min.  
Test time: 16 min. No hazard. 
C166 
sc 
N/A 
Un = 253 V 
R241 opened immediately.  
Test time: 1 min. No hazard. 
C168 
sc 
N/A 
Un = 198 V 
F1 opened immediately, No hazard. 
C170 
sc 
N/A 
Un = 198 V 
R255 and R256 opened immediately. 
No hazard. 
 