Read JBL SUB 550P Service Manual online
Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
Efficiency & Consumption
120V
Efficiency
Efficiency
65
%
65
Test conducted at rated power 245WNominal Line voltage
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 120VAC
5.5
Watts
6.5
@ nom. line voltage 120VAC-60Hz Nominal Line voltage LED=>RED
Idle input power
11
Watts
13
@ nom. line voltage 120VAC-60Hz
Maximum allowable input power under nominal
Input voltage and frequency, HOT or COLD
operation. LED GREEN no signal applied
Input voltage and frequency, HOT or COLD
operation. LED GREEN no signal applied
Power Cons. @ rated power
358
Watts
384
@ nom. line voltage 120VAC-60Hz 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
3.8
ARMS
Reference @ nom. line voltage 120VAC-60Hz
Efficiency & Consumption
230VAC
Efficiency
Efficiency
65
%
62.5
Test conducted at rated power 250WNominal Line voltage
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 230VAC
0.5
Watts
0.55
230VAC, 50-60Hz
Nominal Line voltage LED=>RED
Idle input power
15
Watts
16
@ nom. line voltage and Frequency
Maximum allowable input power under nominal
Input voltage and frequency, HOT or COLD
operation. LED GREEN no signal applied
Input voltage and frequency, HOT or COLD
operation. LED GREEN no signal applied
Power Cons. @ rated power
393
Watts
400
@ nom. line voltage and Frequency 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
2.14
ARMS
Reference @ nom. line voltage and Frequency
Protections
Short Circuit Protection
YES
functional Direct short at output
Amplifier should resume operation after short
circuit condition removal
circuit condition removal
Thermal Protection
YES
functional
@1/8 max unclipped Power at 1.06
times the input voltage
times the input voltage
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker
output under any operating condition including
abnormal operation
output under any operating condition including
abnormal operation
Line Fuse Rating
USA-Domestic 3.15
Amps
3.15
EU
2.5
Amps
2.5
5x20mm Type-T-250 V, Low
Breaking capacity
Breaking capacity
Transformer
Flux Density
Flux Density
<12.5
KGauss
n/a
@ Nom. line voltage
No Audible hum/buzz or excess idle current
Power losses
4.65
Watts
Reference
120VAC-60Hz
Magnetizing current
0.044
Amps
Reference RMS
120VAC-60Hz
All Agency Approvals
YES
n/a
Required per UL/CSA/SEMKO
Standards
Standards
Refer to "Requirements" sheet
Other Parameters/Notes:
1. Limiter circuit response must be clean sounding with no apparent pops, noises, or pumping.
2. Plate dimensions not to exceed 11.81"H x 7.87"W and the plate must be airtight with no possibility of air leaks (plastic cover required).
3. Volume control should be at the input buffer stage in order to lessen the possibility of clipping the input section with highly dynamic audio material.
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE.
1. Limiter circuit response must be clean sounding with no apparent pops, noises, or pumping.
2. Plate dimensions not to exceed 11.81"H x 7.87"W and the plate must be airtight with no possibility of air leaks (plastic cover required).
3. Volume control should be at the input buffer stage in order to lessen the possibility of clipping the input section with highly dynamic audio material.
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE.
Rev-00 July-12-2011, Eng-reference sample
SUB 550P / 230
4