SUB 550P - JBL Audio Service Manual (repair manual). Page 4

Read JBL SUB 550P Service Manual online

Parameter
Specification
Unit
QA Test 
Limits
Conditions
Notes
Efficiency & Consumption 
120V
Efficiency
65
%
65
Test conducted at rated power 245WNominal Line voltage 
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 120VAC
5.5
Watts
6.5
@ nom. line voltage 120VAC-60Hz Nominal Line voltage LED=>RED
Idle input power
11
Watts
13
@ nom. line voltage 120VAC-60Hz
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation. LED GREEN no signal applied
Power Cons. @ rated power
358
Watts
384
@ nom. line voltage 120VAC-60Hz 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
3.8
ARMS
Reference @ nom. line voltage 120VAC-60Hz
Efficiency & Consumption 
230VAC
Efficiency
65
%
62.5
Test conducted at rated power 250WNominal Line voltage 
Efficiency at 1/8 of rated powe
52
%
50
Test conducted at 31.25 WRMS
Nominal Line voltage-Rated impedance 4 Ohms
Standby input power 230VAC
0.5
Watts
0.55
230VAC, 50-60Hz
Nominal Line voltage LED=>RED
Idle input power
15
Watts
16
@ nom. line voltage and Frequency
Maximum allowable  input power under nominal  
Input voltage and frequency, HOT or COLD 
operation. LED GREEN no signal applied
Power Cons. @ rated power
393
Watts
400
@ nom. line voltage and Frequency 250 Watts @ 4 Ohms nominal line voltage
Input Current @ rated power
2.14
ARMS
Reference @ nom. line voltage and Frequency
Protections
Short Circuit Protection 
YES
functional  Direct short at output
Amplifier should resume operation after short 
circuit condition removal 
Thermal Protection 
YES
functional
@1/8 max unclipped Power at 1.06 
times the input voltage
DC Offset Protection
YES
-
DC present at Speaker Out leads
Design must insure no Offset at the speaker 
output  under any operating condition including 
abnormal operation
Line Fuse Rating
USA-Domestic 3.15
Amps
3.15
EU
2.5
Amps
2.5
5x20mm Type-T-250 V, Low 
Breaking capacity
Transformer
Flux Density
<12.5
KGauss
n/a
@ Nom. line voltage
No Audible hum/buzz or excess idle current
Power losses
4.65
Watts
Reference
120VAC-60Hz
Magnetizing current
0.044
Amps
Reference RMS
120VAC-60Hz
All Agency Approvals
YES
n/a
Required per UL/CSA/SEMKO 
Standards
Refer to "Requirements" sheet
Other Parameters/Notes:
1. Limiter circuit response must be clean sounding with no apparent pops, noises, or pumping.
2. Plate dimensions not to exceed 11.81"H x 7.87"W and the plate must be airtight with no possibility of air leaks (plastic cover required).
3. Volume control should be at the input buffer stage  in order to lessen the possibility of clipping the input section with highly dynamic audio material.
4. ALL SPECS SHOULD BE MEASURED AT NOMINAL LINE VOLTAGE. 
Rev-00 July-12-2011, Eng-reference sample
SUB 550P / 230
4
Page of 43
Display