Report No.: TP11100216-ST 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 
N/A 
9.1.1.1 
a) Open circuit voltages  
 
 
b) Touch current measured from terminal devices 
using the network in annex D ................................. : 
253 V/ 60 Hz 
U1: 0.280 Vpeak max. 
U2: 0.067 Vpeak max. 
 
c) Discharge not exceeding 45 
µ
C  
 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
< 15 KV 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No ventilation holes on top 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No such part 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................. : 
  
 
If C is not greater than 0,1 
µ
F no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
  
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
250 N 
9.2 
No hazard after removing a cover by hand  
  
N/A 
 
10 
Insulation requirements 
10.1 
Insulation resistance (M
) at least 2 M
 min. after 
surge test for basic and 4 M
 min. for reinforced 
insulation ................................................................. : 
  
N/A 
10.2 
Humidity treatment 48 h or 120 h  .......................... : 
48 h and 120 h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 