Read JBL SUB 200 (serv.man6) EMC - CB Certificate online
Page 5 of 5
Report No. 711304
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
TABLE: list of critical components and materials
P
Object/Part No.
Manufacturer
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
1
)
Mains
transformer
transformer
Transtec
TT0869803320-E
AC 230-240V
IEC 60065
—
Thermal link
Joint Force
L33
2A, 250V, 130
°C IEC
60691
TÜV
Mains Fuse
Walter
TSD
T1.25AL 250V
IEC 60127
Mains
fuseholder
fuseholder
Chin Shin
(Walter)
R3-11
10A 250V
IEC 60065
—
Min. V-1
IEC 60707
—
Bobbins
Transformer
Transformer
EI Dupont de
Nemours
Nylon 66
101,101F
0.71mm/94V-2 Complies
with
HB75
IEC 60707
—
Cordset:
plug
I Sheng
SP-021A
2.5A 250V
CEE 7
cord
H03VVH2-F
2 x 0.75mm²
IEC 60227
AP-401
2.5A 250V
CEE 7
*)Alt plug
With Cord
Dongguan
Apollo Wires
& Cable Co.,
Ltd
H03VVH2-F
2 x 0.75mm²
IEC 60227
UK Cord set:
Plug with fuse
Luen Tai
Electric
9518
13A 250V
BS 1363
BSI
cord Rhythm
Wire
Ind. Co., Ltd.
H03VVH2-F
2 x 0.75mm²
IEC 60227
KEMA
Mains plug for
Korea
Korea
Volex
MP2217
3A 250V
KS C8305
Mains cord for
Korea
Korea
Volex
VCTFK
2 x 0.75mm²
KS C3304
Mains switch
CHILY
3024
16(4)A, 8/128A
250V Class II
IEC 61058-1
IEC60065:2001 Sub-
clause 14.6.1a)
Sec. connector
P103
JWT
A3963Wv2-5P
Min. V-1
IEC 60707
—
PCB Jian
He
(Cheng Ho)
Various
Min. V-1
IEC 60707
—
1
) An asterisk indicates a mark which assures the agreed level of surveillance.
2
) Description to include adjacent markings for critical fuse/s.
*) New alternative components.