Read JBL SUB 180 EMC - CB Certificate online
page 6 of 28
Ref.No.: 410586
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8.6
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
This clause is not considered.
Noted.
Reinforced or double insulation between circuits
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
N
Separation by Class
ΙΙ isolating transformer
N
Separation by Class
Ι transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation
≥ 0.4 mm (mm) : P
Reinforced insulation
≥ 0.4 mm (mm) ................... : P
Thin sheet insulation
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
In transformer.
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Applies to class
Ι.
N
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
As above.
N
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Mains wires are double
insulated , no secondary wire
can come in to contact with
un-insulated mains.
insulated , no secondary wire
can come in to contact with
un-insulated mains.
P