TP10110019-ST  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
14 (cont.) 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model 
Value/rating 
Standard 
Approval/ 
reference 
1)
 
Insulating Tube 
(T2), (For 
NT1810NL only) 
Changyuan 
CB-TT-S 
600Vac, Max. 
200
°
IEC 60065 
applicable part 
Tested in 
appliance 
Alt. (For 
NT1810NL only) 
Shenzhen Woer 
WF 
600Vac, Max. 
200
°
IEC 60065 
applicable part 
Tested in 
appliance 
Varnish (T2) 
(For NT1810NL 
only) 
Hang Cheung
 
8562C 
155°C 
Applicable parts 
of IEC 60065, UL 
94 
UL recognized 
Bobbin (DT1) 
Chang Chun 
T375J 
V-0, 150
°
Applicable parts 
of IEC 60065,  
UL 94 
UL recognized 
Insulation Tape 
(DT1) 
Jingjiang Yahua  
CT 
130
°
Applicable parts 
of IEC 60065,  
UL 94 
UL recognized 
Alt. 
Suzhou 
Mailaduona 
JY312 
130
°
Applicable parts 
of IEC 60065,  
UL 94 
UL recognized 
Margin Tape 
(DT1) 
Jingjiang Yahua   WF 
130
°
C, 3.0 mm 
wide minimum 
Applicable parts 
of IEC 60065,  
UL 94 
UL recognized 
Insulating Tube 
(DT1) 
Changyuan 
CB-TT-S 
600Vac, Max. 
200
°
IEC 60065 
applicable part 
Tested in 
appliance 
Alt. 
Shenzhen Woer 
WF 
600Vac, Max. 
200
°
IEC 60065 
applicable part 
Tested in 
appliance 
Varnish (DT1) 
Hang Cheung
 
8562C 
155°C 
Applicable parts 
of IEC 60065, UL 
94 
UL recognized 
Note: 
1)  An asterisk indicates a mark which assures the agreed level of surveillance. 
2)  All the plastic material mentioned are checked and found to be acceptable for using in this product. 
Checking date: Same as this report issued data, see also page 1. 
Page of 87
Display

Click on the first or last page to see other SUB 140P service manuals if exist.