Read JBL SUB 140P EMC - CB Certificate online
Page 74 of 75
TP10110019-ST
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
14 (cont.)
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
trademark
Type/model
Value/rating
Standard
Approval/
reference
reference
1)
Insulating Tube
(T2), (For
NT1810NL only)
Changyuan
CB-TT-S
600Vac, Max.
200
°
C
IEC 60065
applicable part
Tested in
appliance
Alt. (For
NT1810NL only)
Shenzhen Woer
WF
600Vac, Max.
200
°
C
IEC 60065
applicable part
Tested in
appliance
Varnish (T2)
(For NT1810NL
only)
Hang Cheung
8562C
155°C
Applicable parts
of IEC 60065, UL
94
UL recognized
Bobbin (DT1)
Chang Chun
T375J
V-0, 150
°
C
Applicable parts
of IEC 60065,
UL 94
UL recognized
Insulation Tape
(DT1)
Jingjiang Yahua
CT
130
°
C
Applicable parts
of IEC 60065,
UL 94
UL recognized
Alt.
Suzhou
Mailaduona
JY312
130
°
C
Applicable parts
of IEC 60065,
UL 94
UL recognized
Margin Tape
(DT1)
Jingjiang Yahua WF
130
°
C, 3.0 mm
wide minimum
Applicable parts
of IEC 60065,
UL 94
UL recognized
Insulating Tube
(DT1)
Changyuan
CB-TT-S
600Vac, Max.
200
°
C
IEC 60065
applicable part
Tested in
appliance
Alt.
Shenzhen Woer
WF
600Vac, Max.
200
°
C
IEC 60065
applicable part
Tested in
appliance
Varnish (DT1)
Hang Cheung
8562C
155°C
Applicable parts
of IEC 60065, UL
94
UL recognized
Note:
1) An asterisk indicates a mark which assures the agreed level of surveillance.
2) All the plastic material mentioned are checked and found to be acceptable for using in this product.
Checking date: Same as this report issued data, see also page 1.
Click on the first or last page to see other SUB 140P service manuals if exist.