SUB 140P (serv.man4) - JBL Audio EMC - CB Certificate (repair manual). Page 6

Read JBL SUB 140P (serv.man4) EMC - CB Certificate online

Report No:W-N-1010002-CY-01-1 
                                                                                                   
Telecom Technology Center 
 
2. SUMMARY OF TEST RESULTS 
 
2.1 Test Result 
The EUT has been tested according to the following specifications: 
 
IMMUNITY(EN 55020: 2007) 
Standard 
Test Type 
Result
Remarks 
Input immunity 
N/A 
The immunity test at antenna 
input terminal of EUT. 
The performance criteria is A 
Immunity to Induced voltages PASS
The immunity test at Audio 
and mains terminal of EUT by 
CDN. 
The performance criteria is A 
Immunity to RF voltage at 
antenna terminal 
N/A 
The immunity test at antenna 
input terminal of EUT by 
CDN. 
The performance criteria is A 
Immunity from radiated 
fields 
PASS
The immunity test at enclosure 
of EUT by open strip line. 
The performance criteria is A 
EN 55020:2007 
Screening effectiveness 
N/A 
The screening effectiveness is 
50dB 
EN 55020:2007 
IEC 61000-4-2: 
2008 ED.2.0 
Electrostatic discharge 
immunity test 
PASS
Contact discharge up to  ±4 kV
Air discharge up to  ±8 kV 
The performance criteria is B 
EN 55020:2007 
IEC 61000-4-3: 
2006+A1:2007 
ED.3.0 
Radiated, radio-frequency, 
electromagnetic field 
immunity test 
PASS
900MHz 
(duty cycle 1/8 , 217Hz 
repetition frequency): 3V/m 
The performance criteria is A 
EN 55020:2007 
IEC 61000-4-4: 
2004 ED.2.0 
Electrical fast transient / burst 
immunity test. 
PASS
±
0.5 kV,  ±1 kV(AC Input) 
The performance criteria is B 
 
The above equipment has been tested by Telecom Technology Center, and found 
compliance with the requirement of the above standards. The test record, data 
evaluation & Equipment Under Test (EUT) configurations represented herein are true 
and accurate accounts of the measurements of the sample’s EMC characteristics under 
the conditions specified in this report. 
Page of 48
Display