Report No.: 1009940
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
9.1.1
For voltages >1000V ac or >1500V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
P
b) Touch current measured from terminal devices
using the network in annex D …………………:
using the network in annex D …………………:
Voltage U1: 0.19V peak
Voltage U2: 0.02V peak
Voltage U2: 0.02V peak
P
c) Discharge not exceeding 45μC
N/A
d) Energy of discharge not exceeding 350mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
P
9.1.3
Ventilation holes and other holes tested by means of
4mm x 100mm test pin
4mm x 100mm test pin
No ventilation holes
N/A
9.1.4
Terminal devices tested with 1mm x 20mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1mm x 100mm straight
wire (1N); test probe D of IEC 61032
wire (1N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100mm test
pin (10N); test probe C of IEC 61032
pin (10N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2s ……………:
of the mains plug; voltage (V) after 2s ……………:
P
If C is not greater than 0.1μF no test needed
N/A
9.1.7
Resistance to external forces
a) Test probe 11 of IEC 61032 for 10s (50N)
P
b) Test hook of fig. 4 for 10s (20N)
P
c) 30mm diameter test tool for 5s (100 or 250N)
P
9.2
No hazard after removing a cover by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2MΩ min. after
surge test for basic and 4MΩ min. for reinforced
insulation …………………………………………..:
surge test for basic and 4MΩ min. for reinforced
insulation …………………………………………..:
N/A
10.2
Humidity treatment 48h or 120h …………………….: Both 48 and 120h
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P