SUB 140 (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 12

Read JBL SUB 140 (serv.man2) EMC - CB Certificate online

 
Page 9 of 54 
Report No.: 1009940 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000V ac or >1500V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1 
a) Open circuit voltages  
 
 
b) Touch current measured from terminal devices 
using the network in annex D …………………: 
Voltage U1: 0.19V peak 
Voltage U2: 0.02V peak 
 
c) Discharge not exceeding 45μC  
 
N/A 
 
d) Energy of discharge not exceeding 350mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
9.1.3 
Ventilation holes and other holes tested by means of 
4mm x 100mm test pin  
No ventilation holes 
N/A 
9.1.4 
Terminal devices tested with 1mm x 20mm test pin 
(10 N); test probe D of IEC 61032  
 P 
 
Terminal devices tested with 1mm x 100mm straight 
wire (1N); test probe D of IEC 61032  
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100mm test 
pin (10N); test probe C of IEC 61032  
 N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2s ……………: 
 P 
 
If C is not greater than 0.1μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
a) Test probe 11 of IEC 61032 for 10s (50N)  
 
 
b) Test hook of fig. 4 for 10s (20N)  
 
 
c) 30mm diameter test tool for 5s (100 or 250N)  
 
9.2 
No hazard after removing a cover by hand  
 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2MΩ min. after 
surge test for basic and 4MΩ min. for reinforced 
insulation …………………………………………..: 
 N/A 
10.2 
Humidity treatment 48h or 120h …………………….:  Both 48 and 120h 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
 P 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 P 
Page of 73