SUB 100P (serv.man2) - JBL Audio Service Manual (repair manual). Page 16

Read JBL SUB 100P (serv.man2) Service Manual online

ARENA SUB100P
JBL 
Released 2015 
Rev0 3/2015 
Part No. 
Description 
Spec 
Qty 
Location(s) 
14040097  SMT IC 
NJM4558 SOP8 JRC 
U106.107.108.105. 
11130005  carbon resister 
1/8W  0
Ω 5% ,horizontal, P=5mm L=4mm 
C130 
14010040  triode 
2N7000,TO92,clubfoot,L=4mm,FAIRCHILD 
Q105 
50060011  MET Cap. 
124/100V ±5% 7.2*6.5*2.5mm L=4mm 
C131.132 
50060056  MET Cap. 
184/63V ±5% 7.2*6.5*2.5mm L=4mm 
C124.126 
50060040  MET Cap. 
563/100V ±5% 7.2*6.5*2.5mm L=4mm 
C127 
50060043  MET Cap. 
683/100V ±5% 7.2*6.5*2.5mm L=4mm 
C125 
17050058 
NP electrolytic 
capacitor 
47uF/25V,105
Ԩ,+/-20%,
Φ6*12mm L=4mm 
C147 
17010004 
electrolytic 
capacitor 
1uF/50V,105℃,+/-20%,
Φ5*11mm L=4mm, 
blue 
C108 
17010032 
electrolytic 
capacitor 
22uF/50V,105
Ԩ,+/-20%,
Φ5*11mm L=4mm 
C104.139 
17010053 
electrolytic 
capacitor 
100uF/25V,105℃
,±20%,
Φ6.3*11mmL=4mm, black 
C101.102.109 
17010073 
electrolytic 
capacitor 
220uF/25V,105
Ԩ,+/-20%,
Φ6.3*12mm 
L=4mm 
C116.115 
18040023  LED(2P) 
PNL2026HRBW&3004RBWH2,
Ф3mm, 
red/blue 
LED1 
12010058  slide switch 
SS-22F12-G8 
SW101.SW102 
40190070  RCA connector 
RCA-208 1P, gold plated 
LFE 
15010210  potentiometer 
R12154G-KQ16A7.5-A503-0B0 
&R1216G1BB4-5-A50K-G-T7.5 
15010024  potentiometer 
R0841G12A1-5-C50K-M7 
VR102 
Misc 
Miscellaneous amplifier parts 
40010007  power socket 
ST-A03-002LC-S 
12030010  power switch 
RS601D-201011BB&PS8A-11-B1B3-5H-
10 
19070001  fuse holder 
R3-11 
19020016  fuse 
2A/250V,5*20mm,melting slowly 
20210005  knob 
GT-29 
16070019  power cord 
US power cord ,SY-11+SY-101,L=1.83m, 
black  