Read JBL SPYRO (serv.man3) EMC - CB Certificate online
Page 10 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N
If C is not greater than 0,1 μF no test needed
< 0, 1 uF
P
9.1.7
Enclosure sufficiently resistant to external force
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Test probe 11 of IEC 61032 for 10 s (50 N)
N
Test hook of fig. 4 for 10 s (20 N)
N
30 mm diameter test tool for 5 s (100 or 250 N) .... :
N
9.2
No hazard after removing a cover by hand
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
10 INSULATION
REQUIREMENTS
N
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
10.2
Humidity treatment 48 h or 120 h ........................... : - Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
- No live parts in apparatus
N
10.3
Insulation resistance and dielectric strength
- Powered 18 Vd.c. by certified
adaptor
- No live parts in apparatus
adaptor
- No live parts in apparatus
N
Click on the first or last page to see other SPYRO (serv.man3) service manuals if exist.