Read JBL SPOT (serv.man3) EMC - CB Certificate online
Page 61 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
Annex B
5th paragraph – add reference to clause 4.2.1.1 in
IEC 62151.
IEC 62151.
Add to 12th paragraph. “The requirements of
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
4.2.1.1 shall be replaced by the requirements or
2.3.1 of UL 60950, Third Edition.”
13th paragraph, 2nd dash replace with: “In the
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2s the voltage limits
of 4.1.2 (35 V peak, or 60 V d.c.) shall apply.”
event of a single insulation fault, the voltages on
the TNV-0 circuits, TNV-1 circuits and accessible
conductive parts shall not exceed the values given
in clause 9.1.1.1a of this standard for more than
0.2s. Moreover, the limits values as given in 11.1
shall not be exceeded. After 0.2s the voltage limits
of 4.1.2 (35 V peak, or 60 V d.c.) shall apply.”
Add to 19th paragraph: “Apparatus intended to be
connected to telecommunication networks and
having ringing voltages applied to the apparatus
ids subjected to touch current limits in accordance
with clause 5.1.8.1.1 of UL 60950, Third
Edition“ Add to 21st
paragraph: ”Telecommunication network that uses
outside cable shall comply with the requirements
for protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
connected to telecommunication networks and
having ringing voltages applied to the apparatus
ids subjected to touch current limits in accordance
with clause 5.1.8.1.1 of UL 60950, Third
Edition“ Add to 21st
paragraph: ”Telecommunication network that uses
outside cable shall comply with the requirements
for protection against overvoltage from power line
crosses per 6.4 of UL 60950, Third Edition”
Add to 22nd paragraph: “Acoustic tests per 6.5 of
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
UL 60950, Third Edition for apparatus containing
earphone held against the ear.”
Add to 24th paragraph: “Apparatus shall be
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
provided with appropriate markings and
instructions as described in Annex NAA of UL
60950, Third Edition.”
No TNV.
N
Annex D
Figure D.1 & Note delete reference to IEC 60990
and add reference to ANSI C101. Add touch
current value in MIU where MIU=U2x2 (r.m.s.
value)
and add reference to ANSI C101. Add touch
current value in MIU where MIU=U2x2 (r.m.s.
value)
N
Annex G
Deleted
N
Annex Q
Add: Safety requirements for video apparatus for
use in health care facilities
use in health care facilities
Not such apparatus.
N
Annex R
Add: Safety requirements founder cabinet
apparatus
apparatus
Not such apparatus.
N
Annex S
Add: Safety requirements for in-wall mounted
apparatus
apparatus
Not such apparatus.
N
Annex T
Add: Safety requirements for apparatus with
projection lamps
projection lamps
Not such apparatus.
N
Annex U
Add: Safety requirements for permanently
connected apparatus
connected apparatus
Not such apparatus.
N
Click on the first or last page to see other SPOT (serv.man3) service manuals if exist.