National Differences 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
Australian National Differences according to CB Bulletin No. 110A, June 2006 
ventilation not exceeding 1 mm in width 
regardless of the length. 
(b)  The following parts which would contribute 
negligible fuel to a fire: 
small mechanical parts, the mass of which 
does not exceed 4 g, such as mounting 
parts, gears, cams, belts and bearings; 
small electrical components, such as 
capacitors with a volume not exceeding 
1750 mm
3
, integrated circuits, transistors and 
optocoupler packages, if these components 
are mounted on material flammability 
category FV-1 or better according to AS/NZS 
4695.707 
NOTE - In considering how to minimize 
propagation of fire and what “small parts” are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part to 
another. 
Compliance is checked by tests of 4.7.201.2, 
4.7.201.3, 4.7.201.4 and 4.7.201.5. 
For the base materials of printed boards, 
compliance is checked by the test of 4.7.201.5. 
The tests shall be carried out on parts of non-
metallic material, which have been removed from 
the apparatus. When the glow-wire test is carried 
out, the parts shall be placed in the same 
orientation, as they would be in normal use. 
These tests are not carried out on internal wiring. 
4.7.201.2 
Parts of non-metallic material are subjected to 
glow wire test of AS/NZS 4695.2.11, which is 
carried out at 550 °C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall be not carried out on parts of 
materials classified at least FH-3 according to 
ISO 9772 provided that the sample was not 
thicker than the relevant part. 
Alternative test methods were 
not considered. 
N/A 
4.7.201.3 
Testing of insulating materials 
Parts of insulating materials supporting potential 
ignition sources shall be subject to the glow-wire 
test of AN/NZS 4695.2.11, which is carried out at 
750 °C. 
The test shall be also carried out on other parts of 
Alternative test methods were 
not considered. 