Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 9 of 48
CS
Signal generator
ROHDE &
SCHWARZ
SML03 103002
2013-11-13
Power meter
BOOTON
4232A
10543
2013-09-26
Amplifier
PRANA R&D
AP32 DT214
0611-768
2014-01-11
CDN
EMC PARTNER
L-801 M2/M3
2265
2014-03-01
Injection Clamp
PRANA R&D
IP-DR250
0603-0729
2013-06-26
VOLTAGE DIP & VOLTAGE INTERRUPTIONS
Main Interference
Simulator
Simulator
EMC PARTNER
TRA2000
851
2013-05-30
3.5 MONITORING OF EUT FOR THE IMMUNITY TEST
Visual:
Monitored the Spectrum Analyzer for any unintentional responses and any external
change by the eyes for RS.
change by the eyes for RS.
Audio:
Hear the sound from EUT by ear for ESD, RS, EFT, SURGE, CS, DIP.
The audio reproduction functionality has been tested in accordance with EN 55013/EN 55020.
The test results may be found in test report EM201300221-3.
The test results may be found in test report EM201300221-3.
Click on the first or last page to see other SPARK (serv.man7) service manuals if exist.