Read JBL SPARK (serv.man6) EMC - CB Certificate online
Report No.:
EM201300221-1
Application No.:
ZJ00028648
Page 13 of 53
4.2 FREQUENCY RANGE
4.2.1 LIMITS
EN300 328 clause 4.3.3
fL > 2,4 GHz and fH < 2,4835 GHz
4.2.2 TEST PROCEDURE
Test EUT in normal conditions, and then repeat in extreme conditions.
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected.
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and 8DPSK test
data.
4.2.3 TEST SETUP
Test EUT in normal conditions, and then repeat in extreme conditions.
Measurement RBW = 100 kHz, VBW ≥ 100 kHz, average mode with 60 second sweeps selected.
Pre-test the 3 modulation to find GFSK and 8DPSK is worse case, so only record GFSK and 8DPSK test
data.
4.2.3 TEST SETUP
4.2.4 TEST RESULTS
Measurement Conditions
Frequency spot with
level ≤ -30dBm/100KHz
level ≤ -30dBm/100KHz
Limit (MHz)
Temperature(°C) Voltage
FL
FH
Lower
Higher
For GFSK
AC Power
25 ACnom
2400.90
2480.70
FL>2400.0 FH< 2483.5
-20
ACmin 2400.81
2480.64
ACmax 2400.82 2480.57
+55
ACmin 2400.79
2480.59
ACmax 2400.77 2480.61
For 8DPSK
AC Power
25 ACnom
25 ACnom
2401.26
2480.75
FL>2400.0 FH< 2483.5
-20
ACmin 2401.09
2480.45
ACmax 2401.15 2480.63
+55
ACmin 2401.14
2480.38
ACmax 2401.23 2480.66
Antenna
EUT
Receiver
Click on the first or last page to see other SPARK (serv.man6) service manuals if exist.