Read JBL SOUNDFLY AIR EMC - CB Certificate online
ATTACHMENT 1
Nation Differences
( 25 / 28 )
Report No. : 12-1330-0044
TRF No. IEC60065K
17.9A
Adhesive securement and conductive coatings
17.9A.
1
1
Add t he f ollow ing clause:
Adhesive securement
Adhesive securement
The f ollow ing part s, t he displacement of
w hich may result in a f ire or shock hazard,
shall not be secured solely by adhesive,
unless t he adhesive syst em complies w it h t he
resist ance t o ext ernal f orces t est of Clause
9.1.7, t he bump t est of Clause 12.1.1, and
t he impact t est of Clause 12.1.3, af t er
condit ioning in accordance w it h Clause
17.9A.2:
w hich may result in a f ire or shock hazard,
shall not be secured solely by adhesive,
unless t he adhesive syst em complies w it h t he
resist ance t o ext ernal f orces t est of Clause
9.1.7, t he bump t est of Clause 12.1.1, and
t he impact t est of Clause 12.1.3, af t er
condit ioning in accordance w it h Clause
17.9A.2:
a) int ernal met al part s/conduct ive coat ings;
b) barriers; and
c) required enclosure part s.
b) barriers; and
c) required enclosure part s.
Not e: Cat hode ray t ubes are excluded f rom
t his t est .
t his t est .
Adhesives/Conduct ive
coat ing not used.
coat ing not used.
N/A
17.9A.
2
2
Adhesive and conductive coating securement conditioning
17.9A.
2.1
2.1
General:
Where required by Clause 17.9A.1, one
sample of t he apparat us or enclosure sect ion
shall be condit ioned in accordance w it h t he
requirement s of Clause 17.9A.2.2.
Equivalent ageing t est dat a supplied by t he
manuf act urer w ill be considered in lieu of
ageing.
sample of t he apparat us or enclosure sect ion
shall be condit ioned in accordance w it h t he
requirement s of Clause 17.9A.2.2.
Equivalent ageing t est dat a supplied by t he
manuf act urer w ill be considered in lieu of
ageing.
N/A
17.9A.2.
2
Ageing
Day 1: Place in oven at 100 ± 1ºC f or 1
w eek, or 82 ± 1ºC f or 8 w eeks at t he
manufacturer’ s option.
Day 1: Place in oven at 100 ± 1ºC f or 1
w eek, or 82 ± 1ºC f or 8 w eeks at t he
manufacturer’ s option.
Day 8 or Day 57:
1. Remove f rom oven and leave at room
t emperat ure f or 1 h.
2. Place in f reezer at
1. Remove f rom oven and leave at room
t emperat ure f or 1 h.
2. Place in f reezer at
–35ºC for 2 h.
3. Remove f rom f reezer and allow t o reach
room t emperat ure overnight .
Day 9 or Day 58:
1. Place in a compart ment at 96% relat ive
humidit y f or 3 h.
2. Remove and leave at room t emperat ure
and humidit y f or 1 h.
3. Place in over at a t emperat ure select ed in
t he f irst cycle f or 3 h.
4. Remove and allow t o come t o room
t emperat ure overnight .
room t emperat ure overnight .
Day 9 or Day 58:
1. Place in a compart ment at 96% relat ive
humidit y f or 3 h.
2. Remove and leave at room t emperat ure
and humidit y f or 1 h.
3. Place in over at a t emperat ure select ed in
t he f irst cycle f or 3 h.
4. Remove and allow t o come t o room
t emperat ure overnight .
N/A
Click on the first or last page to see other SOUNDFLY AIR service manuals if exist.