Read JBL SDP-40 HD (serv.man4) EMC - CB Certificate online
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax 887 6445
Page 7 of 143
Test Number- 250-05
TEST PROCEDURES and EQUIPMENT
3. TEST PROCEDURES (cont.)
Conducted test procedure:
The power line of the EUT is connected to the LISN (Line Impedance
Stabilization Network). A measurement of the emissions are made from the
power line for both phase A and phase B on the analyzer in the frequency range
from 150 kHz to 30 MHz. The maximum readings are recorded for each phase.
power line for both phase A and phase B on the analyzer in the frequency range
from 150 kHz to 30 MHz. The maximum readings are recorded for each phase.
Disturbance power test procedure:
The EUT, associated cables and peripheral devices are placed on the
supporting table with any support equipment placed off the site. The EUT is
turned on and any necessary operating or test software installed and is
allowed to warm up. A cable of 6 meters (or maximum length possible) is
placed into the clamp. The frequency band from 30 MHz to 300 MHz is scanned.
The clamp is moved along the length of cable. When a signal is found the
emission is measured by moving the clamp to the area of the cable where the
maximum signal can be obtained. The maximum reading is recorded and the next
signal is searched for. The test is repeated on all interconnecting cables.
turned on and any necessary operating or test software installed and is
allowed to warm up. A cable of 6 meters (or maximum length possible) is
placed into the clamp. The frequency band from 30 MHz to 300 MHz is scanned.
The clamp is moved along the length of cable. When a signal is found the
emission is measured by moving the clamp to the area of the cable where the
maximum signal can be obtained. The maximum reading is recorded and the next
signal is searched for. The test is repeated on all interconnecting cables.
All measurements are made according to the procedures defined in:
"EN55013: 2001 Sound and television broadcast receivers and associated
equipment- Radio disturbance characteristics- Limits and methods of
measurement." Also, the procedures defined in "EN55022: 1994 Limits and
methods of measurement of radio disturbance characteristics of information
technology equipment" & "ACA AS/NZ 3548:1995 Limits and methods of measurement
of radio disturbance characteristics of information technology equipment" are
taken into account during Radiated and Conducted measurements for the purpose
of including FCC and Canadian Requirements.
equipment- Radio disturbance characteristics- Limits and methods of
measurement." Also, the procedures defined in "EN55022: 1994 Limits and
methods of measurement of radio disturbance characteristics of information
technology equipment" & "ACA AS/NZ 3548:1995 Limits and methods of measurement
of radio disturbance characteristics of information technology equipment" are
taken into account during Radiated and Conducted measurements for the purpose
of including FCC and Canadian Requirements.