Read JBL SDP-40 HD (serv.man2) EMC - CB Certificate online
Test Number - 251-05
Harman Specialty Group
Lexicon Digital Controller - MC-12 with HDMI interfaces
2.0
EN 61000-4-2 ELECTROSTATIC DISCHARGE TEST DESCRIPTION
2.1 TEST SETUP
The EUT setup was placed in the ESD test laboratory in accordance with the IEC
standard, with the following climatic conditions:
Temperature: 24.1
degrees
C
Relative Humidity: 31 %
The EUT was connected as diagrammed in Section 1.3 of this report.
A horizontal coupling plane (HCP) was placed on a non-conductive table, 0,8 meters
above the ground plane and connected to the ground plane through two 470-kohm
resistors. The EUT was placed on the table with an insulating support between the EUT
and the HCP. The ESD simulator was charged and allowed to discharge through the
HCP See section 9 for photographs of typical setups.
A vertical coupling plane (VCP) measuring 0,5m by 0,5m was fixed 0,1m from the
vertical surfaces of the equipment, parallel to them and connected to the ground plane
through two series 470 kohm resistors. The ESD simulator was charged and allowed to
discharge to the VCP. This test was repeated until all vertical surface areas of the EUT
were exposed to the VCP.
The ESD events were applied to such points and surfaces of the EUT that are normally
accessible to the operator for normal operation or maintenance. Contact discharge is
the preferred test method. Air discharges are used where contact discharge cannot be
applied.
NOTES:
1.
See Section 2.5, for ESD test locations.
Compliance Worldwide, Inc. - 357 Main Street - Sandown, NH 03873
(603) 887 3903 Fax (603) 887 6445
www.complianceworldwide.com
Page 11 of 29
Click on the first or last page to see other SDP-40 HD (serv.man2) service manuals if exist.