SCS 140 (serv.man10) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL SCS 140 (serv.man10) EMC - CB Certificate online

 
Page 9 of 46 
Report No. 704079 
 IEC 
60065
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
 
TRF No.: IEC60065F 
 
TRF Originator: ASTA BEAB 
 
8.12 
This sub-clause is void 
 
N/A 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s) 
 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges (2N force) 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
8.19.1 
Disconnect device 
Mains plug 
 
All-pole switch or circuit breaker with >3mm contact 
separation 
 N/A 
8.19.2 
Mains switch ON indication 
 
N/A 
8.20 Switch 
not 
fitted 
in the mains cord 
 
8.21 
Bridging components comply with clause 14 
 
N/A 
8.22 
Test of non-separable thin sheet material 
 
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1    a)  Determination of Hazardous Live parts 
 
b)  Touch current measured from terminal devices 
using the network in annex D  ................................: 
See table 9 
c)  Discharge not exceeding 45 μC  
N/A 
d)  Energy of discharge not exceeding 350 mJ 
 
N/A 
9.1.1.2 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
No ventilation holes 
N/A 
9.1.4 
Terminal devices - within 25mm tested with 
1 mm x 20 mm test pin (10 N); test probe D of IEC 
61032 
 P 
Page of 74
Display