Read JBL S-820 EMC - CB Certificate online
mikes-testingpartners gmbh
File
No.
F32090-00-00HM
, page
11 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Test point:
N
Operation mode:
1 kHz 1/8 rated output power
Remarks: Ground
connection
Date: 15.
October
Tested by:
Michael Hackl
Result: passed
Peak Measurement
See Table for QP and AV v alues
N OM1
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
A
m
p
lit
ude
dB
(µ
V
)
File Number:
Standard:
Equipment -
Serial No. -
Op Mode 1 -
Operator -
LmtAVVoltage
LmtQPVoltage
Peak_21
AVG_21
QP_21
AV_21
LmtQPVoltage
Peak_21
AVG_21
QP_21
AV_21
Frequency
QP Level
QP Margin
QP Limit
AV Level
AV Margin
AV Limit
MHz dB(µV) dB dB dB(µV) dB dB
0.000
22.2
22.2 22 22.2 22.2 22
0.155 58.9 -6.9 65.7 27.1 -28.6 55.7
0.22 48.0
0.22 48.0
-14.8 62.8 17.0 -35.8 52.8
0.5 35.4
-20.6
56.0 6.2
-39.8 46.0
0.6 51.7
-4.3 56.0 17.0 -29.0 46.0
0.615 51.5 -4.5 56.0 17.1 -28.9 46.0
0.72 32.7
0.72 32.7
-23.3 56.0 3.3
-42.7 46.0
0.975 35.1 -20.9 56.0 4.1
-41.9 46.0
1.16 52 -4.0 56.0
18.0 -28.0 46.0
1.44 36.9
-19.1 56.0 4.8
-41.2 46.0
1.715 50.7 -5.3 56.0
2.455 42.7 -13.3 56.0 11.4 -34.6 46.0
3.07 36.8
2.455 42.7 -13.3 56.0 11.4 -34.6 46.0
3.07 36.8
-19.2 56.0 9.0
-37.0 46.0