Read JBL S-5160 (serv.man2) EMC - CB Certificate online
File
No.
F24989-00-00HM
, page 26 of 31
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.7.3 Test
specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Air discharge
- Contact discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- see photo documentation of the test set-up
- all external locations accessible by hand
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- all external locations accessible by hand
- horizontal plate (HCP)
- vertical coupling plate (VCP)
5.7.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave was disturbed.
Operation mode: 1 kHz, 1/8 nominal output power.
Click on the first or last page to see other S-5160 (serv.man2) service manuals if exist.