Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
44 of 50 
 
 
APPENDIX B 
B. Nemko USA, Inc. Test Equipment & Facilities Calibration Program 
 
Nemko USA, Inc. operates a comprehensive Periodic Calibration Program in order to ensure the validity of all 
test data.  Nemko USA’s Periodic Calibration Program is fully compliant to the requirements of NVLAP Policy 
Guide PG-1-1988, ANSI/NCSL Z540-1-1994, ISO 10012: 2003, ISO/IEC 17025:1999, and ISO-9000: 2000.  
Nemko USA, Inc.’s calibrations program therefore meets or exceeds the US national commercial and military 
requirements [N.B. ANSI/NCSL Z540-1-1994 replaces MIL-STD-45662A]. 
 
Specifically, all of Nemko USA’s primary reference standard devices (e.g. vector voltmeters, multimeters, 
attenuators and terminations, RF power meters and their detector heads, oscilloscope mainframes and plug-ins, 
spectrum analyzers, RF preselectors, quasi-peak adapters, interference analyzers, impulse generators, signal 
generators and pulse/function generators, field-strength meters and their detector heads, etc.) and certain 
secondary standard devices
 (e.g. RF Preamplifiers used in CISPR 11/22 and FCC Part 15/18 tests) are 
periodically recalibrated by: 
 
o  A Nemko USA-approved  independent (third party) metrology laboratory that uses NIST-
traceable standards and that is ISO Guide 25-accredited as a calibration laboratories by NIST; or, 
o  A Nemko USA-approved  independent (third party) metrology laboratory that uses NIST-
traceable standards and that is ISO Guide 25-accredited as a calibration laboratory by another 
accreditation body (such as A2LA) that is mutually recognized by NIST; or, 
o  A manufacturer of Measurement and Test Equipment (M&TE), if the manufacturer uses NIST-
traceable standards and is ISO Guide 25-accredited as calibration laboratory either by NIST or by 
another accreditation body (such as A2LA) that is mutually recognized by NIST; or 
o  A manufacturer of M&TE (or by a Nemko USA-approved  independent third party metrology 
laboratory) that is not ISO Guide 25-accredited.  (In these cases, Nemko USA conducts an annual 
audit of the manufacturer or metrology laboratory for the purposes of proving traceabilty to 
NIST, ensuring that adequate and repeatable calibration procedures are being applied, and 
verifying conformity with the other requirements of ISO Guide 25). 