Read JBL RADIAL MICRO (serv.man3) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
April 8, 2008
Harman Multimedia - JBL Radial Micro - EMC Test Report
2006 100765 EMC Rev.1
8 of 74
1.2.2. Immunity Test Summary
Test Methods
Minimum Criterion
Level Required
as per EN 55024
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2: 1995/A1:
1998/A2: 2000
1998/A2: 2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-6000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast Transient
-Electrical Fast Transient
Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
up to ±2kV process/control lines;
I/O Line Pulses of ± 0.5 kV
PASS
IEC 61000-4-5: 2005
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion B
±2kV Common Mode Surges,
±1kV Differential Mode
Surges
PASS
IEC 61000-4-6: 2003/A1:
2004/A2: 2006
-RF Common Mode
2004/A2: 2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion B
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
*
PASS
IEC 61000-4-8: 1993/A1:
2000
Power Frequency Magnetic
Field
Field
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Not Required
IEC 61000-4-11: 2004
- Voltage Dips and Short
- Voltage Dips and Short
Interruptions
Criterion B and C
Voltage Dips of 30% and >95%;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30% and
>95%; Interruptions of >95%.
PASS
*
Client accepts a lowered criterion for this test.
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.
Click on the first or last page to see other RADIAL MICRO (serv.man3) service manuals if exist.