PSW-D112 (serv.man4) - JBL Audio Service Manual (repair manual). Page 2

Read JBL PSW-D112 (serv.man4) Service Manual online

SAFETY INFORMATION
Warning
Caution
Leakage/Resistance Check
List of Safety Components Requiring
Exact Replacements
(all parts POWER AMP PCB except TR2)
C6 (Rev0)
4.7uf 100V 80/-20% Electrolytic redial NP
C6 (Rev1)
4.7uf 100V 80/-20% Electrolytic redial NP
TR2
MPS A13 30V NPN(Darl)
R4a/b/c
0.1 0.5W 5% metal film
R9
3.3 5W 5% ceramic wirewound
R15
100k 0.5W 5% carbon film
DBR
Bridge Rect 200V Use only factory replacement.
R1
10M 0.25W 5% carbon film
R16, 17
1.8k 5W 5% ceramic wirewound
R33 (Rev0) only) 332 0.5W 5% carbon film
R50 (Rev0) only) 332 0.5W 5% carbon film
R52, 57
2.7k 5W 5% ceramic wirewound
R61
3.9k 3W 5% carbon film
S64AMI
Power output module.  Use only factory
replacement
Faceplate
Faceplate.  Use only factory replacement
CMC1
Use only factory replacement
L1
Use only factory replacement
Fuse PCB
Use only factory replacement
Main PCB
Use only factory replacement
4700uF,50V electrolytic filter caps.  Be sure
replacement part is at least the same
working voltage and capacitance rating.
Also the lead spacing is important.
Incorrect spacing may cause premature
failure due to internal cabinet pressure and
vibration.
2
Amplifier/Subwoofer
PSW-D110/DPS-10
F1
PWRCORD
TRX1
C1, 2
Transformer.  Use only factory replacement.
SPT-2 or better with polarized plug, UL
approved wire with the hot side to fused
side.  Use with factory replacement panel
strain relief only.
Fuse SLO BLO 1.25A 250V UL approved
Any person performing service of this unit will be exposed 
to hazardous voltages and the risk of electric shock.  It is 
assumed that any person who removes the amplifier from 
this cabinet has been properly trained in protecting against 
avoidable injury and shock.  Therefore, any service 
procedures are to be performed by qualified service 
personal ONLY!
Before returning the unit to the customer, perform a 
leakage or resistance test as follows:
Leakage Current. Note there is no power switch on this 
unit.  When the power plug  is plugged in, the unit is live.  
Connect the unit to its rated power source.  Using an 
ammeter, measure the current between the neutral side of 
the AC supply and chassis ground of the unit under test.  If 
leakage current exceeds 0.5A, the unit is defective.  
Reverse the polarity of the AC supply and repeat.
Resistance.  Measure the resistance from either side of the 
line cord to chassis ground.  If it is less than 500k ohms, the 
unit is defective.
WARNING!  DO NOT return the unit to the customer if it 
fails one of these tests until the problem is located and 
corrected.
This unit does not have a power switch.  Hazardous 
voltages are present within the unit whenever it is 
plugged in.
Before the amplifier is plugged in, be sure its rated voltage 
corresponds to the voltage of the AC power source to be 
used.  Incorrect voltage could cause damage to the 
amplifier when the AC power cord is plugged in.  Do not 
exceed rated voltage by more than 10%: operation below 
90% of rated voltage will cause poor performance or may 
shut the unit off.
0
0
4
6
5
-2
IMPORTANT SERVICE NOTES:  When testing the PSW-D112/DPS-12 Series amplifier, a load must always be
connected to the output terminals, whether the woofer, or a 4 to 8 ohm resistive load.
All AC powered test instruments (meters, oscilloscopes, etc.) must have a floating ground, i.e., be
connected to an isolation transformer.
Critical Components
All components identified with the IEC symbol 
in the parts list and the schematic diagram 
designate components in which safety can be 
of special significance when replacing a 
component identified with      .  Use only the
replacement parts designated in the parts list or parts with 
the same rating of resistance, wattage or voltage.
Page of 35
Display

Click on the first or last page to see other PSW-D112 (serv.man4) service manuals if exist.