Read JBL ON TOUR XTB (serv.man5) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 - Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
Error! Reference
source not
found.
Harman Multimedia - On Tour XTB - RTTE Test Report
2009 11138368 EMC
7 of 73
Template 7-09aal
1.2.2.
Immunity Test Summary
Specification
Minimum Criterion
Level Required
as per ETSI EN 301 489-1
V1.8.1 (2008-04)
Criterion Level
Tested
Compliance
Status
EN 61000-4-2: 2009
-ESD Immunity
-ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
EN 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz;
1000-2700 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz;
1000-2700 MHz
(80% AM at 1kHz)
PASS
EN 61000-4-4: 2004
-Electrical Fast
-Electrical Fast
Transient Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
I/O Line Pulses of ± 0.5 kV
PASS
EN 61000-4-5: 2006
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion B
±2kV common mode surges,
±1kV differential mode surges
PASS
EN 61000-4-6: 2009
-RF Common Mode
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
EN 61000-4-11: 2004
-Voltage Dips and
-Voltage Dips and
Short Interruptions
Criterion B and C
Voltage Dips of 30%, 60% and;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30%, 60%;
Interruptions of >95%.
PASS
Refer to the test results section for further details.