3. Practical Explanation of the Meaning of Radiated Emissions Measurement Uncertainties
In general, a “Statement of Measurement Uncertainty” means that with a certain (specified) confidence
level, the “true” value of a measurand will be between a (stated) upper bound and a (stated) lower
bound.
In the specific case of EMC Measurements in this test report, the measurement uncertainties of the
conducted emissions measurements and the radiated emissions measurements have been calculated
in accordance with the method detailed in the following documents:
In general, a “Statement of Measurement Uncertainty” means that with a certain (specified) confidence
level, the “true” value of a measurand will be between a (stated) upper bound and a (stated) lower
bound.
In the specific case of EMC Measurements in this test report, the measurement uncertainties of the
conducted emissions measurements and the radiated emissions measurements have been calculated
in accordance with the method detailed in the following documents:
o
ANSI Z540.2 (2002) Guide to the Expression of Uncertainty in Measurement
o
NIS
81:1994,
The Treatment of Uncertainty in EMC Measurements (NAMAS, 1994)
o
NIST Technical Note 1297(1994), Guidelines for Evaluating and Expressing the Uncertainty of
NIST Measurement Results (NIST, 1994)
The calculation method used in these documents requires that the stated uncertainty of the
measurements be expressed as an “expanded uncertainty”, U, with a k=2 coverage factor. The
practical interpretation of this method of expressing measurement uncertainty is shown in the following
example:
EXAMPLE: Assume that at 39.51 MHz, the (measured) radiated emissions level was equal to
+26.5 dBuV/m, and that the +/- 2 standard deviations (i.e. 95% confidence level) measurement
uncertainty was +/- 3.4 dB.
+26.5 dBuV/m, and that the +/- 2 standard deviations (i.e. 95% confidence level) measurement
uncertainty was +/- 3.4 dB.