Read JBL ON TOUR XT (serv.man5) EMC - CB Certificate online
12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to electrical transients (EN 55020 - Sec. 5.6)
5.0
Test
Point
pos
neg
pos
neg
pos
neg
pos
neg
pos
neg
Power L
A
A
A
A
B(1)
B(1)
--
--
--
--
Power N
A
A
A
A
B(1)
B(1)
--
--
--
--
Input Voltage: 230VAC, 50Hz
Ambient Temperature:
21
o
C
Ground Strap used: Yes
Relative Humidity: 50%
EFT observed on oscilloscope: Yes
Atmospheric Pressure: 972mbar
0.5kV
Test level, polarity, and result classification
1kHz Tone
1 kV
2 kV
4 kV
Mode of operation
0.25kV
Notes:
EUT has a 2 line only Wall Wort, no protected earth.
Note 1: + or -1kV causes a disruption in sound and volume of EUT. Sound disruption ceases at
termination of interference.
EUT has a 2 line only Wall Wort, no protected earth.
Note 1: + or -1kV causes a disruption in sound and volume of EUT. Sound disruption ceases at
termination of interference.
Data:
Page 9 of 27
EMC Report for Harman Consumer Group on the JBL On Tour II
Click on the first or last page to see other ON TOUR XT (serv.man5) service manuals if exist.