ON TOUR XT (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 23

Read JBL ON TOUR XT (serv.man5) EMC - CB Certificate online

12/05/2006
Report Number: 3109671ATL-005
Issued:
Intertek
Measurement of immunity to eletrostatic discharge (EN 55020 - Sec. 5.9)
8.0
Method:
In the case of air discharges, the round discharge tip of the discharge electrode shall be approached as fast as possible (without causing mechanical 
damage) to touch the EUT. After each discharge, the ESD generator (discharge electrode) shall be removed from the EUT. The generator is then 
retriggered for a new single discharge. This procedure shall be repeated until the discharges are completed. In the case of an air discharge test, the 
discharge switch, which is used for contact discharge, shall be closed.
Indirect application of the discharge:
Discharges to objects placed or installed near the EUT shall be simulated by applying the discharges of the ESD generator to a coupling plane, in the 
contact discharge mode. 
Horizontal coupling plane (HCP) under the EUT:
Discharge to the HCP shall be made horizontally to the edge of the HCP.  At least 10 single discharges (in the most sensitive polarity) shall be applied at the 
front edge of each HCP opposite the centre point of each unit (if applicable) of the EUT and 0.1 m from the front of the EUT. The long axis of the discharge 
electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge.  The discharge electrode shall be in contact with the 
edge of the HCP. In addition, consideration should be given to exposing all sides of the EUT to this test.
Vertical coupling plane:
At least 10 single discharges (in the most sensitive polarity) shall be applied to the centre of one vertical edge of the coupling plane. The coupling plane, of 
dimensions 0.5 m x 0.5 m, is placed parallel to, and positioned at a distance of 0.1 m from, the EUT. Discharges shall be applied to the coupling plane, with 
sufficient different positions such that the four faces of the EUT are completely illuminated.
Description:
Manufacturer:
Model:
Asset Number:
Cal Date:
Cal Due:
Test Equipment Used:
Digital Pocket Weathermeter
Mannix
SAM700BAR
211896
10/13/2006
10/13/2007
Electrostatic Discharge Gun (ESD)
NoiseKen
TC-815P
200068
06/06/2006
06/06/2007
Electrostatic Discharge Simulator (ESD)
Noiseken
ESS-200AX
014450
06/06/2006
06/06/2007
Vertical Coupling Plane
ITS
ESD-VCP
213119
VBU
VBU
Results:  The sample tested was found to Comply.
Page 23 of 27
EMC Report for  Harman Consumer Group on the JBL On Tour II
Page of 27
Display

Click on the first or last page to see other ON TOUR XT (serv.man5) service manuals if exist.