Read JBL ON TOUR XT (serv.man3) EMC - CB Certificate online
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 19 of 27
4.3.3
Disturbance Power Data
Standard:
CISPR
13
Measurement
Uncertainty:
2.6dB
Company: Harman Multimedia Consumer Group
Temperature: 24°C
Job Number: 3109671LAX-009
Relative Humidity: 49%
Model: JBL On Tour XT
Input power line (with AC 100 VAC 50 Hz):
Input power line (with AC 100 VAC 50 Hz):
Frequency Peak AV
Limit Margin
MHz (dBpW) (dBpW) (dBpW)
32.0 27.1 35.2 -8.1
36.8 27.9 35.8 -7.9
61.5 27.5 38.0 -10.5
91.8 33.7 39.8 -6.1
94.9 30.2 39.9 -9.7
138.1 30.3 41.6 -11.3
Input power line (with AC 100 VAC 60 Hz):
Frequency Peak AV
Limit Margin
MHz (dBpW) (dBpW) (dBpW)
32.0 27.3 35.2 -7.9
36.8 28.9 35.8 -6.9
61.5 26.8 38.0 -11.2
91.8 34.6 39.8 -5.2
94.9 32.1 39.9 -7.8
138.1 31.5 41.6 -10.1
Click on the first or last page to see other ON TOUR XT (serv.man3) service manuals if exist.