Read JBL ON TOUR (serv.man14) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 13, 2004
Harman Multimedia JBL Ontour EMC
Test Report
2004 040110 CFV Rev 1
59 of 80
6.9. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature
72
deg C
PAN #
24-110-HARa
Relative Humidity
46
%
EUT Name
Speaker System
Barometric Pressure
30.2
Hg
EUT Model
JBL Ontour
Test Location
Enclosure 2
Governing Doc
EN 55024
Test Engineer
Mike Krumweide
Basic Standard
EN 61000-4-6
Date
4/9/04
Test Level:
X
3Vrms
10Vrms
Modulation:
None (CW)
X
80%AM @ 1kHz
Frequency Range:
X
0.15 – 80 MHz
0.15-230MHz
Step:
X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria:
A
X
B
1
Injection Point (Cable)
AC Mains
Injection Method:
Clamp
X
CDN
Comments:
1kHz tone heard 40-80MHz in background è Meets manufacturers criteria.
2
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
3
Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
4
Injection Point (Cable)
Injection Method:
Comments:
5
Injection Point (Cable)
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used
Calibration Done
Calibration Due
HP 8462B (Signal Generator)
751
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
X
8/25/03
8/25/04
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
X
7/18/03
7/18/03
FCC-801-M3-25 (CDN)
466
X
1/13/04
1/13/05
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 10A250 (Amplifier)
402
X
NCR
NCR
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Solar 6741-1N (Clamp)
144
Compliant X
Non-Compliant
Photo X
Click on the first or last page to see other ON TOUR (serv.man14) service manuals if exist.