Read JBL ON TIME 200ID (serv.man2) EMC - CB Certificate online
<12014165 001>
Page 28 of 73
IEC60065E
ASTABEAB
Temperature Rise dT of Part
dT (K)
Limit dT (K)
PCB under BR1
61,4
46,0
85
PCB under D3
52,8
55,3
85
PCB under Q1
53,3
46,4
85
Electrolytic capacitor (C1)
49,1
38,8
60
Optocoupler (IC2)
39,0
38,0
55
X2 capacitor (CX1)
37,8
30,6
55
Y1 capacitor (CY1)
34,5
32,5
80
Output cord
18,7
18,8
35
Inside enclosure
34,8
36,5
69
Outside enclosure
35,2
37,1
50
Ambient (°C)
45,0
45,0
--
Model S024EV0600300
T1 winding
57,6
58,5
65
T1 core
56,8
57,6
--
L1 winding
58,1
44,8
85
PCB under BR1
57,4
42,8
85
PCB under D3
59,4
57,1
85
PCB under Q1
48,3
42,4
85
Electrolytic capacitor (C1)
47,9
38,0
60
Optocoupler (IC2)
41,4
38,4
55
X2 capacitor (CX1)
34,5
26,1
55
Y1 capacitor (CY1)
35,1
32,1
80
Output cord
25,9
25,1
35
Inside enclosure
44,0
45,4
69
Outside enclosure
33,9
34,9
50
Ambient (°C)
45,0
45,0
--
Model S024EV0300300
T1 winding
39,0
39,5
65
T1 core
38,0
38,5
--
L1 winding
42,6
33,2
85
PCB under BR1
38,5
29,9
85
PCB under D3
41,3
40,2
85
Click on the first or last page to see other ON TIME 200ID (serv.man2) service manuals if exist.