ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 60

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

IEC 60950-1 1st. Ed, 2001 
- Page 2 of 5 - 
 
 
 
Order No.  46974 
 
   
 
1.7.1 
Equipment for use on supply systems with a 
neutral and more than one phase conductor 
(e.g. 120/240 V, 3-wire) require a special 
marking format for electrical ratings.  
A voltage rating that exceeds an attachment 
plug cap rating is only permitted if it does not 
exceed the extreme operating conditions in 
Table 2 of CAN/CSA C22.2 No. 235, and if it is 
part of a range that extends into the Table 2 
“Normal Operating Conditions”. Likewise, a 
voltage rating shall not be lower than the 
specified “Normal Operating Conditions”, 
unless it is part of a range that extends into the 
“Normal Operating Conditions”.  
Class III equipment. 
N/A 
2.5 
Where a fuse is used to provide Class 2, 
Limited Power Source (or TNV) current 
limiting, it shall not be operator-accessible 
unless it is not interchangeable.  
No such fuses provided. 
N/A 
2.7.1 
Suitable NEC/CEC branch circuit protection 
rated at the maximum circuit rating is required 
for all standard supply outlets, receptacles and 
medium-base or smaller lampholders if the 
supply branch circuit protection is not suitable. 
Power distribution transformers distributing 
power at 100 volts or more, and rated 10 kVA 
or more, require transformer overcurrent 
protection. 
No standard supply outlets, 
receptacles, lampholders or such 
transformers. 
N/A 
3.2 
Wiring methods (terminals, leads etc.) used for 
the connection of the equipment to the mains 
shall be in accordance with the NEC/CEC.  
Class III equipment. 
N/A 
3.2.1 
Power supply cords are required to have 
attachment plugs rated not less than 125 
percent of the rated current of the equipment.  
Class III equipment. 
N/A 
3.2.3 
Permanent connection of equipment to the 
mains supply by a power supply cord is not 
permitted, except for certain equipment, such 
as ATMs.  
Class III equipmen, not 
permanently connected to the 
mains. 
N/A 
3.2.5 
Power supply cords are required to be no 
longer than 4.5m in length. 
Flexible power supply cords are required to be 
compatible with Article 400 of the NEC, and 
Tables 11 and 12 of the CEC.  
Class III equipment. 
N/A 
3.2.9 
Permanently connected equipment is required 
to have a suitable wiring compartment and wire 
bending space.  
Class III equipmen, not 
permanently connected to the 
mains. 
N/A 
3.3 
Wiring terminals and associated spacings for 
field wiring connections shall comply with CSA 
C22.2 No. 0.  
Class III equipment. 
N/A 
3.3.3 
Wire binding screws are not permitted to attach 
conductors larger than 10 AWG (5.3mm
2
).  
Class III equipment. 
N/A 