ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 23

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

 
 
- Page 23 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
Normal load condition per Annex L .....................:  Normal operation is considered 
1/8th of maximum undistorted. 
Non-clipping was determined 
using a 1 KHz sinusoidal signal 
input. For maximum normal 
operation, 1/8th of the non-
clipping amplitude was used 
with a filtered pink noise input 
signal. 
4.5.2 
Resistance to abnormal heat 
No thermoplastic parts carrying 
hazardous voltages. 
N/A 
 
4.6 Openings 
in 
enclosures 
 
4.6.1 
Top and side openings 
No top and side openings. 
N/A 
 Dimensions 
(mm) 
...............................................: 
 
— 
4.6.2 
Bottoms of fire enclosures 
No bottom openings. 
N/A 
 
Construction of the bottom..................................:   
— 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers provided. 
N/A 
4.6.4 
Openings in transportable equipment 
The unit is not regarded as 
transportable equipment. 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by adhesive 
inside enclosure. 
N/A 
 
Conditioning temperature (
°C)/time (weeks).......:   
— 
 
4.7 
Resistance to fire 
 
4.7.1 
Reducing the risk of ignition and spread of flame 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 1, selection and application of 
components wiring and materials 
Equipment is class III 
equipment, powered from a 
LPS. 
 
Method 2, application of all of simulated fault 
condition tests 
 N/A 
4.7.2 
Conditions for a fire enclosure 
Equipment is class III 
equipment, powered from a 
LPS. Fire enclosure is not 
considered necessary. 
N/A 
4.7.2.1 
Parts requiring a fire enclosure 
Refer to 4.7.2. 
N/A 