ON STAGEII (serv.man12) - JBL Audio EMC - CB Certificate (repair manual). Page 58

Read JBL ON STAGEII (serv.man12) EMC - CB Certificate online

IEC 60950-1 1st. Ed, 2001 
- Page 6 of 6 - 
 
 
 
Order No.  46974 
 
 
6.2.2.1 
Add the symbol NZ in the right hand margin 
beside the first paragraph including Note 1. 
Delete Note 2 
Add the following after the first paragraph: 
In Australia (this variation does not apply in 
New Zealand), the electrical separation is 
subjected to 10 impulses of alternating 
polarity, using the impulse test generator of 
annex N for 10/700µs impulses. The interval 
between successive impulses is 60 s 
and the initial voltage, Uc, is: 
for 6.2.1 a):7.0 kV for hand-held telephones 
and for headsets and 2.5 kV for other 
equipment; and 
for 6.2.1 b) and 6.2.1 c):1.5 kV. 
NOTE 201 – The 7 kV impulse simulates 
lightning surges on typical rural and semi-rural 
network lines. 
NOTE 202 – The value of 2.5 kV for 6.2.1 a) 
was chosen to ensure the adequacy of the 
insulation concerned and does not necessarily 
simulate likely overvoltages. 
No TNV circuitry. 
N/A 
6.2.2.2 
Add the symbol NZ in the right hand margin 
beside the second paragraph. 
Delete the Note. 
Add the following after the second paragraph: 
In Australia (this variation does not apply in 
New Zealand), the a.c. test voltage is: 
for 6.2.1 a):3 kV; and 
for 6.2.1 b) and 6.2.1 c):1.5 kV. 
NOTE 201 – Where there are capacitors 
across the insulation under test, it is 
recommended that d.c. test voltages are used. 
NOTE 202 – The 3 kV and 1.5 kV values have 
been determined considering the low 
frequency induced voltages from the power 
supply distribution system. 
No TNV circuitry. 
N/A 
Annex P 
Add the following Normative References to Annex P:
IEC 60065, Audio, Video and similar electronic 
apparatus—Safety requirements 
AS/NZS 3191, Approval and test specification—
Electric flexible cords 
AS/NZS 3112, Approval and test specification—
Plugs and socket-outlets 
AS/NZS 4695.707, Fire hazard testing of 
electrotechnical products—Methods of test for the 
determination of the flammability 
of solid electrical insulating materials when exposed 
to an igniting source 
Considered. 
 
Index 
Between the entries for ‘polyimide insulating 
material’ and ‘powder’ insert the following: 
potential ignition source 1.12.201, 4.7.201.3, 
4.7.201.5 
Considered. N/A 
 