ON STAGE (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 3

Read JBL ON STAGE (serv.man3) EMC - CB Certificate online

 
 
 
 
- Page 3 of 19 - 
 
 
   
 
Order No.  23171 
 
 
 
SUMMARY OF TESTING : 
 
Sub -clause  
Information/Remarks 
Comments 
1.2.2.1
 
Normal load as described in Annex L or as close 
as possible to the most severe normal use.  
Normal operation is considered 1/8
th
 of maximum 
undistorted.  Non-clipping was determined using a 
1 KHz sinusoidal signal input.  For maximum 
normal operation, 1/8
th
 of the non-clipping 
amplitude was used with a filtered pink noise input 
signal. 
1.7.2 
Safety instructions, required markings regarding 
use of a specified power supply. 
Class III Equipment with an enclosure made of 
HB-Material, using a non-special connector for the 
DC input must have a marking stating the 
manufacturer and model number of the power 
supply to be used.  Marking is provided. 
1.7.12  
Language of safety markings/instruction. 
Instructions and equipment marking related to 
safety shall be applied in a language, which is 
acceptable in the country in which the equipment 
is to be sold. 
3.2 
Connection to the supply. 
Unit is powered by a limited power source  
complying with Sub-clause 2.11. The external 
power supply was not evaluated in this test report. 
 
Page of 55