Read JBL ON STAGE III IIIP (serv.man6) EMC - CB Certificate online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 12 of 66
3.5. EUT Configuration on Test
The following equipments are installed on conducted emission test to meet EN55022
requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
3.5.1. Computer Speaker System (EUT)
Model Number
:
jbl on stage lll
Serial Number
: N/A
Manufacturer(1)
:
Zhao Yang Elec. (Shenzhen) Co., Ltd
Manufacturer(2)
:
Jie Hao Elec. (Su Zhou) Co., Ltd
3.5.2.Support Equipment : As Tested Supporting System Detail, in Section 2.2.
3.6. Operating Condition of EUT
3.6.1.Setup the EUT and simulator as shown as Section 3.2.
3.6.2.Turn on the power of all equipment.
3.6.3.Let the EUT work in test mode (Data Transmitting) and measure it.
3.7. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT
Via PC Power connected to the power mains through a line impedance stabilization
network (L.I.S.N. 1#). The other peripheral devices power cord connected to the power
mains through a line impedance stabilization network (L.I.S.N.#3). This provided a
50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test
setup and photographs). Both sides of power line were checked for maximum conducted
interference. In order to find the maximum emission, the relative positions of equipments
and all of the interface cables were changed according to EN 55022 Class B on conducted
Disturbance test.
network (L.I.S.N. 1#). The other peripheral devices power cord connected to the power
mains through a line impedance stabilization network (L.I.S.N.#3). This provided a
50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test
setup and photographs). Both sides of power line were checked for maximum conducted
interference. In order to find the maximum emission, the relative positions of equipments
and all of the interface cables were changed according to EN 55022 Class B on conducted
Disturbance test.
The bandwidth of the test receiver (R&S Test Receiver ESHS10) is set at 10kHz.
The frequency range from 150 kHz to 30 MHz is investigated. The test data and the
scanning waveform are listed in Section 3.8.
Click on the first or last page to see other ON STAGE III IIIP (serv.man6) service manuals if exist.