ON STAGE 200ID - JBL Audio EMC - CB Certificate (repair manual). Page 31

Read JBL ON STAGE 200ID EMC - CB Certificate online

 
 
- Page 30 of 63 - 
 
 
 Report 
No. 
98323 
 
 
IEC 60950-1:2005 / EN 60950-1:2006 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
TRF No. IECEN60950_1C 
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.2 Electric 
strength 
⎯ 
5.2.1 
General 
Functional insulation, no test 
required. 
5.2.2 
Test procedure  
 
 
Measuring instrument 
Inv. no. 
Date 
 
 
 
 
 
 
 
5.3 
Abnormal operating and fault conditions 
⎯ 
5.3.1 
Protection against overload and abnormal operation 
(see appended table 5.3)  
5.3.2 
Motors 
There is no motor in the 
equipment. 
5.3.3 
Transformers 
There are no safety 
transformers in the 
equipment. 
5.3.4 Functional 
insulation .............................................: Complies with c). 
5.3.5 
Electromechanical components 
No electromechanical 
components in secondary 
circuits. 
5.3.6 
Audio amplifiers in ITE .........................................: 
See the enclosed fault 
condition tests. 
5.3.7 
Simulation of faults 
See the enclosed fault 
condition tests. 
5.3.8 Unattended 
equipment 
No 
thermostats, temperauter 
limiters or thermal cut-outs. 
5.3.9 
Compliance criteria for abnormal operating and fault 
conditions 
See below. 
5.3.9.1 
During the tests 
No fire or molten metal 
occurred and no deformation 
of enclosure during the tests. 
Page of 103
Display