Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 30 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Measuring instrument
Inv. no.
Date
5.2 Electric
strength
⎯
5.2.1
General
Functional insulation, no test
required.
required.
N
5.2.2
Test procedure
N
Measuring instrument
Inv. no.
Date
5.3
Abnormal operating and fault conditions
⎯
5.3.1
Protection against overload and abnormal operation
(see appended table 5.3)
P
5.3.2
Motors
There is no motor in the
equipment.
equipment.
N
5.3.3
Transformers
There are no safety
transformers in the
equipment.
transformers in the
equipment.
N
5.3.4 Functional
insulation .............................................: Complies with c).
P
5.3.5
Electromechanical components
No electromechanical
components in secondary
circuits.
components in secondary
circuits.
N
5.3.6
Audio amplifiers in ITE .........................................:
See the enclosed fault
condition tests.
condition tests.
P
5.3.7
Simulation of faults
See the enclosed fault
condition tests.
condition tests.
P
5.3.8 Unattended
equipment
No
thermostats, temperauter
limiters or thermal cut-outs.
N
5.3.9
Compliance criteria for abnormal operating and fault
conditions
conditions
See below.
P
5.3.9.1
During the tests
No fire or molten metal
occurred and no deformation
of enclosure during the tests.
occurred and no deformation
of enclosure during the tests.
P