Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 10 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.8.3
Symbols according to IEC 60417.........................:
The ON/OFF (push-push)
switch is marked with the
switch is marked with the
symbol "
" (IEC 60417-1 No.
5010).
P
1.7.8.4 Markings
using figures .......................................:
N
1.7.9
Isolation of multiple power sources .....................:
Class III equipment.
N
1.7.10
Thermostats and other regulating devices ..........:
No thermostats or other
regulating devices.
regulating devices.
N
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12
Removable parts
No removable parts.
N
1.7.13 Replaceable
batteries ..........................................:
No battery in the equipment.
N
Language(s)
........................................................:
⎯
1.7.14
Equipment for restricted access locations ...........:
Equipment not intended for
intallation in RAL.
intallation in RAL.
N
2
PROTECTION FROM HAZARDS
—
2.1
Protection from electric shock and energy hazards
—
2.1.1
Protection in operator access areas
Refer below:
—
2.1.1.1
Access to energized parts
Class III equipment.
N
Test by inspection .................................................:
—
Test with test finger (Figure 2A) ............................:
—
Test with test pin (Figure 2B) ................................:
—
Test with test probe (Figure 2C) ...........................:
—
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N
2.1.1.5 Energy
hazards .....................................................:
Class III equipment, supplies
from a LPS.
from a LPS.
N