Read JBL ON STAGE 200ID (serv.man3) EMC - CB Certificate online
Ident. Nr.:
98323
Date:
2008-3-11
98323__EMC_TRF
page 6 of 46
2 Summary
Immunity
2.1 Standards
Generic standard
--
Product or product family standard
EN55024:1998+A1:2001+A2:2003
Product category:
--
Performance criteria:
see table below
2.2 Results
Environmental
phenomena
phenomena
Port / Test module
Basic standard and test setup
Performance criteria
Result
Electrostatic
discharge, ESD
discharge, ESD
Enclosure
EN 61000-4-2:1995/A1:
1998/A2:2001
1998/A2:2001
B Pass
Radiated immunity
Enclosure
80 - 1000 MHz
80 - 1000 MHz
EN 61000-4-3:2006
A Pass
Electrical Fast
Transients/Bursts
Immunity
Transients/Bursts
Immunity
Input AC power ports EN 61000-4-4:2004
B Pass
Surge Immunity
Input AC power ports EN 61000-4-5:2006
B Pass
Conducted Immunity
Input AC power ports EN 61000-4-6:1996/A1:2001
A Pass
Voltage dips and
interruptions
Immunity
interruptions
Immunity
Input AC power ports EN 61000-4-11:2004
B for 0% 0.5
C for 0% 250
C for 70% 25
Pass
Remark:EUT not contain components susceptible to magnetic fields,so N/A for Power-frequency
magnetic field test .
magnetic field test .
For details see test modules